FLUID CONTROL

Fluid Control

Complete valve, fitting, metering pump, and flow monitoring systems for chemical liquids, high-purity media, and cooling loops. Select models based on operating conditions—from medium compatibility to dry-run states—rather than assembling from a catalog.

9

Fluid Control Components

18

Industry-specific experience

2

Authorized Distributor of Pneumatic Brands

Why is a dedicated solution required for fluid control?

Pneumatic circuit design focuses on pressure and stroke. For liquid systems, additional factors must be considered: Will the medium corrode wetted materials? Will dripping occur during shutdown? Could leaks arise from multiple fittings? Are abnormalities detectable? Issues discovered during commissioning typically incur higher costs than those addressed during the design phase.

  • Wetted parts material selection based on media type; fluoropolymer and PEEK structures are prioritized for corrosive media.
  • For low flow control, observe the liquid break state; back-suction and tubing length also affect results.
  • Complete valve, fitting, and tubing assemblies to minimize leak points from on-site mixing.
  • Add flow and pressure monitoring to critical branches for anomaly detection and traceability.
  • After installation, perform staged pressure holding and functional testing before commencing continuous production.

Prepare before the communication plan

01Medium Name, Concentration, and Presence of Particles
02Operating Temperature and Cleaning Temperature
03Single-shot volume and strokes per minute
04Supply Pressure, Allowable Pressure Drop, and Pipe Diameter
05Installation Orientation, Maintenance Clearance, and Interface Specifications
Send us the operating conditions.

Component responsibilities for a complete fluid line

Configure in flow order to avoid replacing only one step.

  1. 1Supply and Storage

    Reservoir, Supply Pump, and Level Confirmation

  2. 2Filter and Voltage Regulation

    Filters, Pressure Reducers, and Pulsation Dampeners

  3. 3Monitor

    Flow, Pressure, and Temperature Signals

  4. 4Valve-controlled

    On/Off, Switching, and Drainback Anti-Drip

  5. 5Dose Dispense

    Metering pumps deliver output in cycles.

  6. 6Recycle and Waste Removal

    Draining, Purging, and Waste Collection

Product Categories

Nine component categories organized by Valves, Isolation & Proportional Control, Fittings, Pumps, Monitoring, Cooling, and Integration. Access corresponding product lines directly to view specifications and order part numbers.

View all proxy products
Fluoropolymer Pneumatic ValveFluoropolymer Pneumatic Valve

Fluoropolymer Valves

Fluoropolymer Pneumatic Valve

On/off and switching for low-flow chemical liquids. Valve body and wetted parts are primarily fluoropolymer, suitable for corrosive media and clean piping systems.

  • 2-way, 3-way, and high-flow pneumatic structures to meet diverse flow path requirements.
  • Pneumatically actuated; solenoid valves can be centrally located away from liquid areas.
  • Compatible with PFA, PTFE tubing, and fluororesin fittings
F-AV / F-DAV / F-AVB SeriesView Fluoropolymer Valve
Check valve and solenoid valveCheck valve and solenoid valve

Suck Back & Solenoid

Check valve and solenoid valve

Creates a suction pull-back upon closure to prevent residual liquid dripping and stringing in the tubing. Ideal for dispensing, aliquoting, and applications requiring clean fluid cutoff.

  • Adjustable backflow volume; set according to tubing length and liquid viscosity.
  • Electromagnetic Pilot and Pneumatic Control Drive Methods
  • Paired with a metering pump to reduce wait time for liquid flow interruption.
F-SV / F-SAV / F-EV120 SeriesView Suction and Solenoid Valve
PEEK Isolation Valve and Rocker ValvePEEK Isolation Valve and Rocker Valve

PEEK Isolation Valves

PEEK Isolation Valve and Rocker Valve

Isolation structure for life sciences and analytical instruments featuring PEEK wetted parts. Delivers heat-free actuation for on/off and distribution of corrosive gas-liquid media.

  • Swing-arm isolation structure, ideal for analyzer distribution processes
  • Direct 1.6 / 2.0mm bore or Pneumatic 1.6mm bore
  • A single solenoid valve can control 1 or 2 air valves.
PVR / PVS SeriesView Isolation Valve
Proportional Flow ValveProportional Flow Valve

Proportional Flow Valves

Proportional Flow Valve

Stepless flow control for air, gas, and liquids. Three valve sizes with multiple orifice combinations; pairs with KFPC1 controller to simplify drive wiring and parameter tuning.

  • Three valve body sizes with multiple bore options
  • Continuous adjustment for air, gas, and liquid
  • Models compliant with ISO 10993 standards
Fluororesin Fittings and PipingFluororesin Fittings and Piping

Fittings & Tubing

Fluororesin Fittings and Piping

Fittings, tubes, and functional valves are supplied as matched sets based on medium type and installation space, reducing leak points caused by mixing incompatible specifications on-site.

  • Straight, Elbow, Tee, and Reducer Configurations
  • PTFE and PFA tubing options available to suit various cleanroom classes
  • Fits tubing within the same series; assembly dimensions are consistent.
F-H Series and Functional ConnectorsView Fluororesin Fittings
Peristaltic pumpPeristaltic pump

Dispense Pumps

Peristaltic pump

Dispense adhesive and chemicals by volume using either pneumatic or servo-electric actuators. Select based on dispense rate and cycle time.

  • Programmable electric servo drive with stable repeatability accuracy
  • Pneumatic bellows structure is suitable for low to medium viscosity fluids.
  • Integrates with automated production line communication and external signals
F-EPP / F-EPR / F-EPH / F-EPT / F-APP / F-APBView Dosing Pump
Traffic and Pressure MonitoringTraffic and Pressure Monitoring

Flow & Pressure

Traffic and Pressure Monitoring

Add readable flow and pressure signals to the liquid supply and gas supply branches, turning "feeling normal" into measurable values.

  • Water: Digital flow sensor with integrated flow and temperature display
  • Digital airflow switch with support for both switching and analog output.
  • Digital pressure switch for branch low-pressure and flow-loss alarms
SMC PF3W / PF2A Digital Pressure SwitchView monitoring components
Liquid Cooling Circulation & Temperature ControlLiquid Cooling Loop & Temperature Control

Cooling Loop

Liquid Cooling Circulation & Temperature Control

The cooling loop between the equipment and the chiller is designed based on thermal load, with flow and temperature monitoring to maintain stable operation.

  • Chilled water plate cooling and CDU configuration by thermal load
  • Closed-loop system minimizes water quality fluctuations and prevents pipe condensation
  • Quick-connect fittings and branch pipes support zone-specific maintenance.
COMPUCOOL Liquid Cooling Units and Quick ConnectorsView Liquid Cooling Products
Integrated valve manifold and pipingIntegrated valve manifold and piping

Valve Manifolds

Valve and piping integration

Consolidate scattered valves, fittings, and sensors onto a single mounting plate or manifold to reduce tubing length and minimize on-site assembly variability.

  • Arrange valves by media compatibility and flow path sequence.
  • Reserved manual isolation, purge, and waste discharge interfaces
  • Leak and functional tests performed prior to shipment; connect piping on-site per drawings.
Customize by operating conditionsInquire about integration solutions

Four-Step Roadmap

First, verify if it's usable. Next, confirm if there's enough capacity. Finally, check if it fits.

01

Confirm the medium and concentration first.

The medium determines wetted materials and seals; concentration and temperature define the operating range. Avoid selecting a part number first, then revising the material later.

  • Medium Name and Concentration
  • Operating Temperature Range
  • Contains particles or prone to crystallization
02

Finalize flow rate and pressure

Select valve size and pump specifications based on single-discharge volume, frequency, and line resistance; include adjustment margin instead of selecting at the upper limit.

  • Single Dispense Volume
  • Actions per minute
  • Supply pressure and pressure drop
03

Align interface and mounting space

Fitting specifications, pipe diameter, and installation direction affect assembly and maintenance. Prioritize valve manifold integration in tight spaces.

  • Pipe Diameter and Fitting Specifications
  • Installation Direction and Maintenance Clearance
  • Need to suck back or vent?
04

On-site Validation & Spare Parts

After installation, perform staged pressure testing and operational tests. Prepare seals and valve cores per the spare parts list to minimize downtime.

  • Segmented pressure-holding leak test
  • Action and Traffic Recalibration
  • Spare Parts and Consumables List

Liquid Contact Material Comparison

Material determines the compatible media range; seals and temperature further narrow the usable interval. Use this table for preliminary screening. Final confirmation must be based on the sample chemical resistance chart and media compatibility data.

Temperature limits depend on seal material; for high-temperature applications, verify the valve body, seals, and piping together.

MaterialMedia adaptationTemperature RangeTypical Site
PTFEStrong acids, strong bases, and most organic solvents-20 ~ 150℃Valve body, seals, piping
Please find attached.High-Purity Chemicals and Corrosive Media-20 ~ 150℃High-purity tubing and fittings liners
PEEKFor applications requiring both chemical resistance and wear resistance-20 ~ 150℃Valve core, isolation structural component
Page Object ModelNeutral liquids and weak acids/bases-10 ~ 80℃Analyzer, Dispensing Micro-Valve

Typical Use Cases

The same valve assembly requires different focus areas under varying operating conditions. The following four scenarios serve as a reference for solutions.

Semiconductor Wet Process and Chemical Supply

Transporting acids, bases, and solvents from supply cabinets to equipment focuses on wetted material compatibility, connector sealing integrity, and branch switching cleanliness.

Corrosion-resistant valve componentsFluoropolymer PipingBranch isolation
View related cases

Precision Dispensing & Liquid Handling

Adhesive volume and liquid breakage status directly impact yield. Using a volumetric metering pump with a retraction valve reduces stringing and dripping.

Dose DispenseAnti-drip backflowChangeover parameters
View related cases

Analytical Instruments and Laboratory Flow Paths

Compact, low-flow, and frequent switching require valves and fittings to remain serviceable in tight spaces.

Low volumeCompact layoutClean and purge
View small flow valves

Device and Computing Power Liquid Cooling Loop

Monitor flow rate, temperature, and pressure drop of the coolant loop. Quick couplings enable zone maintenance without draining the entire circuit.

Cooling loopTraffic MonitoringPartition Maintenance
View liquid cooling cases

Cooling Combo

How do cabinet air conditioners work with liquid cooling solutions?

In high power density cabinets, heat sources extend beyond a single chip: inverters, power modules, cables, and cabinet conduction all contribute. The common approach is to use liquid cooling to remove the primary heat load while cabinet air conditioning manages residual heat and environmental control. This division of labor ensures more stable internal temperatures.

Primary heat source uses liquid cooling.

COMPUCOOL cold plates and CDUs extract heat from CPUs, GPUs, variable-frequency drives, and power modules. Heat is centrally dissipated via the water system, making them ideal for high power density applications requiring proximity to heat sources. Key considerations include water quality, flow rate, and pressure drop.

Heat from the cabinet is routed to the air conditioning system.

Rittal Blue e and Blue e+ cabinet air conditioners manage heat transfer from the cabinet, cables, and auxiliary components to maintain internal temperature ranges. With an external circuit rated IP34 and an internal circuit rated IP54, two independent loops minimize dust ingress into the cabinet.

Transition air/water heat exchanger

When an air/water heat exchanger is used to transfer heat from the cabinet to the water system—because a cold plate cannot be installed inside and a water system already exists—the cabinet remains sealed to prevent workshop dust and oil from entering.

Thermal flow path diagram

Liquid cooling extracts the primary heat load; air conditioning manages residual heat within the cabinet; and the heat exchanger facilitates thermal transfer for the sealed enclosure.

Schematic of Thermal Flow Paths for Rack Air Conditioning and Liquid Cooling SolutionsThe liquid cooling loop transfers heat from components via cold plates to the CDU and into the water circuit. Hot air inside the cabinet is exhausted outdoors by the cabinet's air conditioner. The sealed cabinet can also transfer heat to the chilled water loop through an air-to-water heat exchanger.Liquid Cooling Loop · Primary Heat SourceHeating elementVariable Frequency Drives / Power Supplies / ChipsCold plateExtract heat from nearby thermal sourcesCDUCycling and Flow RegulationOutbound waterway transportChiller / Cooling TowerIn-Cabinet Air · Waste HeatHot air inside the cabinetCables and AccessoriesCabinet Air ConditionerBlue e / Blue e+Cabinet temperature rangeOuter Loop IP34 / Inner Loop IP54Exhaust heat from outside the cabinetCondensate is evaporated by the electric system.Transitional Solution · Enclosed CabinetCabinet airNo dust entering the workshopAir/Water Heat ExchangerHeat transfer from the cabinet to the water systemChilled water circuitShared with water-cooled unitsHeat effluxCalculated based on water temperature and flow rate
Liquid cooling loopAir CircuitSchematic indicates heat flow trends only; pipe diameter, flow rate, and temperature difference are calculated based on operating conditions.
Rittal Cabinet Air Conditioner Mounting Options: Side Wall-Mounted, Top-Load, and Door-Mounted
The image shows three installation types: side-wall mount, top-of-cabinet mount, and door mount. Internal circulation delivers air into the cabinet, while external circulation exhausts heat to the surrounding space.

Four things to verify during coordination

Heat flux distribution

Split by device power consumption: Cold plates and CDUs handle the primary heat-generating components, while cabinet air conditioners manage the remaining thermal load and ensure uniform temperature within the rack. This prevents duplicate sizing on both sides based on total heat.

Temperature Setting

First, set the target temperature inside the cabinet, then match the liquid cooling supply temperature and the air conditioner setpoint. A large difference between the two settings can cause them to conflict, leading to equipment cycling on and off repeatedly.

Condensate and Insulation

When supply water temperature drops below the dew point inside the cabinet, pipes may condense; insulation and condensate drainage are required. Condensate from the air conditioning side is handled by an electric condensate evaporator; ensure sufficient clearance for inspection at the installation location.

Installation & Maintenance

Reserve piping routes, quick-connect fittings, and drainage space on the liquid cooling side; maintain airflow clearance on the HVAC side. Perform maintenance separately: monitor water quality and flow rate for liquid cooling, and inspect filters and condensers for HVAC.

FAQ

Frequently asked questions about media compatibility, dry-run conditions, and complete kit configurations.

Provide the medium name, concentration, and operating temperature. We will cross-reference our chemical resistance chart to select compatible materials, then confirm the seal and piping materials. For mixed media or uncommon formulations, we recommend conducting a small-scale test before finalizing the bulk solution.

Specify the medium and operating conditions, and we will provide a configuration list.

Specify media name, concentration, temperature, discharge rate, and interface specifications to organize valves, fittings, tubing, and monitoring components by flow path.

PNEUMAC

Shenzhen Newmak Technology Co., Ltd.

Shenzhen Pneumac Technology Co., Ltd.

Semiconductor Process · Smart Control · System Integration

PNEUMAC is a systems integrator in the control sector, specializing in semiconductor process and intelligent control. As an authorized distributor of industrial systems from multiple brands, we provide solutions for pneumatic components, vacuum pumps, process gas valves, industrial PCs, linear motors and precision stages, liquid-cooled temperature control, and structural components. Professional, honest, efficient, innovative, and committed to sustainable growth!

Contact Us

Yanxi R&D Center, Floor 17, No. 11 Gaoxin West Road, Guangming District, ShenzhenRoom 06, Floor 17, Yanxiang R&D Center, No. 11 Gaoxin West Road, Guangming District, Shenzhen, Guangdong, P.R. China

Copyright Notice

Some images and text on this site are sourced from public networks for product display and technical exchange purposes only. If you believe any content infringes your rights, please contact us and we will address it promptly. Thank you for your understanding!

Contact Email:info@airpptech.com|Contact Us

© 2026 Shenzhen Newmak Technology Co., Ltd.Copyright

Guangdong ICP Record No. 17092872-1